Current Control Unit (UKT) for KIP HS and KIP HS.TN
BUILT-IN EQUIPMENT
Application area
Current control unit (UKT) are designed for embedding in KIP HS and KIP HS.TN and used for measurement of the current of anode groundbeds and protectors.
KIP can be equipped with 1-4 UKT units.
UKT board has special stationary interchangeable instrument shunts (4 or 6 pcs), and also measuring and power terminals. UKT board with six shunts is presented in the following figure.
Ratings of instrument shunts: 1А/75mV or 20А/75mV (on request it is possible to install other shunts, with a rated current of no more than 50 A).
Technical data
Parameter name | Value | |
---|---|---|
Type of instrument shunts | 1 A/75 mV | 20 A/75 mV |
Accuracy of instrument shunts, %, no more than | 0,5 | |
Protection degree | IP 34 to GOST 14254 | |
Range of operation temperatures, °C | from -40 to +50 | |
Weight of KIP with UKT assembled, kg, no more than | 18 |
Conventions
KIP XXXXX | - | UKT | - | 20 | - | 4 | TU 3435-027-24707490-2010, OKPD2 27.12.31.000 |
|||
1 | 2 | 3 | 4 | |||||||
1 | Conventional value KIP HS or KIP HS.TN | |||||||||
2 | Built-in unit: UKT – current control unit; |
|||||||||
3 | Nominal current of measuring shunt UKT: 1, 20 A; |
|||||||||
4 | Number of instrument shunts in UKT: 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 pcs. |
|||||||||