UZZ - Protection Ground Unit for KIP HS and KIP HS.TN
BUILT-IN EQUIPMENT
Application area
Protection ground unit (UZZ) are designed for embedding in KIP HS and KIP HS.TN and used for lightning protection of pipelines and other metal constructions.
KIP with UZZ is a plastic column with built-in board with the device of protection against impulse overvoltage and noises.
Technical data
Parameter name | Value | |
---|---|---|
UZZ-50-L | UZZ-100-L.VZ | |
Kind of plastic stand | triangular | quadrangular |
Class of pulse current according to GOST IEC 62561-3 | N | Н |
Pulse current, kA | 50 | 100 |
Explosion-proof device of protection against pulse overvoltage and noise | no | yes |
Insulation resistance, MOhm, not less | 100 | |
Protection degree | IP 34 to GOST 14254 | |
Range of working temperatures, °C | from -40 to +45 | from -60 to +60 |
Weight of KIP with UZZ assembled, kg, no more than | 18 | |
Grounding | galvanized metal strip 5x50xL, where «L» – strip length |
Conventions
KIP XXXXX | - | UZZ | - | 100 | - | 20 | . | VZ | TU 3435-027-24707490-2010, OKPD2 27.12.31.000 |
|||
1 | 2 | 3 | 4 | 5 | ||||||||
1 | Conventional value KIP HS or KIP HS.TN | |||||||||||
2 | Built-in unit: UZZ – protection ground unit; |
|||||||||||
3 | Pulse current of the discharger, kA; | |||||||||||
4 | Length of the grounding conductor, m; | |||||||||||
5 | The discharger execution: VZ – explosion-proof |
|||||||||||