Manufacturing company «Chemservice» named А.Zorin (CJSC «Chemservice»)
Official site

CORROSION PROTECTION AS AN ART FORM
OFFICIAL SITE OF CHEMSERVICE COMPANY
RELIABLE PROTECTION
OF YUOR EQUIPMENT
IS WORTH OF USING
Telegram VK

Mendeleevets- MKG / Mendeleevets- FPGK
deep, complete silicon iron anodes

Anode MKG / FPGK
Mendeleevets-MKG, Mendeleevets-FPGK
Mendeleevets-MKG, Mendeleevets-FPGK

Mendeleevets-MKG, Mendeleevets-FPGK
Mendeleevets-MKG, Mendeleevets-FPGK
Included in the registers:
Included in the register of GAZPROM Included in the register of TRANSNEFT

Certification:

Certified in the EAC Certified in the INTERGAZCERT Certified in the TRANSNEFT Certified in the GAZCERT Favourable decision of a Sanitary-hygienic Commission of Experts 100 best products 2017
"Менделеевец"-МКГ
  1. silicon iron electrode;
  2. connecting cable;
  3. coke-mineral activator (CMA);
  4. groundbed case;
  5. corbels;
  6. gas outlet tube;
  7. centralizer

Application area

Complete deep groundbeds Mendeleevets-MKG / Mendeleevets- FPGK are used as elements of deep anode ground for installation in the soils with high specific resistance. Groundbeds are installed into boreholes in vertical position.

Technical details

Complete groundbed Mendeleevets-MKG / Mendeleevets- FPGK is a container with silicon iron electrode inside, and the hollow space around it is filled with a cokemineral activator (KMA). Container is a case for comfort transportation and installation. This case dissolves during exploitation.

The groundbed is fixed by means of directing corbels. It gives the possibility to assemble the blocks of complete deep groundbeds into the chain that allows to raise current loading and to reduce transitional resistance. Max block quantity in a chain is 16 pieces.

Комплект глубинных анодных заземлителей «Менделеевец»—МКГ

Gas that is formed while working of deep groundbed is drawn outside to the surface through the gas outlet tube. The gas outlet tube has perforation along all the height of the chain and is delivered for the the concrete order on the basis of one tube for one chain of groundbeds installed in the borehole. The length of the gas outlet tube is equal to the depth of the borehole.

The kind of deep ground, consisting of groundbeds Mendeleevets-MKG/Mendeleevets- FPGK (quantity of blocks in a borehole, quantity of boreholes, distance between boreholes, etc.) is determined by the project of cathodic protection.

As exploitation experience shows complete groundbeds have minimum time period of going out to operating modes and low value of resistance to current spreading. High degree of factory readiness noticeably simplifies the technology of anode groundbeds installation.

Each block has a connecting cable. The length of the cable is determined by the depth of installation in the borehole, that’s why the cable doesn’t have any discontinuities along the length and they are drawn outside to the surface to be attached to the anodic cable line.

Technical data

Parameter nameMendeleevets-MKG
TU 3435-040-24707490-2016
Mendeleevets-FPGK
TU 27.12.31-051-24707490-2021
Current load, A, no more than 8,8 15
Anodic dissolution rate, kg/(A∙year), no more than 0,25 0,15
Active surface area of electrode (working element), м2, no more than: 0.29 0.29
Nominal anode weight, kg 43 43
Assembled anode dimensions , mm, no more than:
- Length (height)
- Diameter

1760х210

1760х210
Weight of the anode block assembly (excluding cable), kg, no more 75 75
The maximum number of grounding blocks in the well, pcs., no more 20 20
Lifetime, years, no less than 35 30
Certification: INTERGAZSERT,
TRANSNEFT
GAZSERT,
is undergoing the INTERGAZSERT
certification procedure

Delivery set

NAME OF COMPONENTSКОЛИЧЕСТВО
Set of anodes (the design, number and length of the cable are
determined by the requirements of the Customer), set
1
Trunk (connecting) cable, м (according to the order)
Operating documentation according to GOST R 2.601, set 1
Certified copy of certificate or declaration of compliance with technical regulations 1
Protocol of acceptance-testing, copy 1
Kit of materials and fittings for anodes, kit* 1
(as ordered)
Packing list, copy 1
* The kit is delivered according to the specifications of the cathodic protection project or
in accordance with Customer’s requirements

Mendeleevets- MKG (TU 3435-040-24707490-2016, OKPD2 27.12.31.000)

20 MKG - 60 х 10 (PKZ-PvP) - 50 х 16 (VVGng) - TM . G
1 2 3 4 5 6 7 8 9
included in the order
if necessary
1
Number of anodes devices included, pcs.: no more than 20;
2
Depth of the anodes well, m;
3
Anode cable core section, mm2: 10, on request:16;
4
Anode cable type: PKZ-PvP,
on request: PKZ-PvPp, PKZ-FF-ng(A);
5
Anode cable length, m;
6
Main cable core section, mm2: 16, on request: 25;
7
Main cable type: VVGng,
on request: PKZ PvP, PKZ-PvPp, PKZ-FF-ng(A);
8
Cable joint kits:
cable clamps (KZ), thermit welding (TS), cable terminations (TM),
or their combinations (KZ+TM, TS+TM)
9
Complete set of gas outlet pipe( by default, it is included in the delivery package)

Mendeleevets- FPGK (ТУ 3435-040-24707490-2016, OKPD2 27.12.31.000)

20 F P G К (1х43) - 60 х 10 (PKZ-PvP) - 50 х 16 (VVGng) - ТМ . G
1 2 3 4 5 6 7 8 9 10 11 12 13 14
included in the order
if necessary
1
The number of anodes in the kit: for standard anodes-no more than 4 pcs., for block anodes-no more than 20 pcs;
2
Material of the electrode (working element) of the anode: F (ferrosilide);
3
Application conditions: P (subsurface);
4
Construction and method of placement in the ground: G (deep);
5
The presence of an electrically conductive backfill (KMA) in the anode design: К;
6
NxM - the number of electrodes in the anode N (4 pcs. for a standard or 1 pc. for a block anode) and the nominal mass of one electrode M (43 kg);
7
Anode cable length, m;
8
Main cable core section, mm2: 10, 16, 25;
9
Anode cable type: PKZ-PvP,
on request: PKZ-PvPp, PKZ-FF-ng(A);
10
Length of the main cable, m;
11
Main cable core section, mm2: 10, 16, 25;
12
Main cable type: VVGng,
on request: PKZ PvP, PKZ-PvPp, PKZ-FF-ng(A);
13
Cable joint kits:
cable clamps (KZ), thermit welding (TS), cable terminations (TM),
or their combinations (KZ+TM, TS+TM)
14
Additional equipment: G-exhaust pipe (if necessary)